5. Tuning
— 5-3 —
5.2.1. Precautions for Automatic Tuning
!
Danger : Before performing the automatic tuning, be sure to wire the following
input signals so that the Motor can stop immediately in case of
emergency.
!
Danger : The Motor will rotate for ± 20° during the automatic tuning in order to
estimate the Load moment of inertia. Do not enter the range of Motor
rotations.
!
Caution : The Motor may vibrate at the end of automatic tuning if rigidity of the load
is insufficient. In such a case turn the Motor servo off by the following
way. Then increase the rigidity or perform manual tuning to continue the
tuning.
Make the input EMST (Emergency stop) OFF
Make the input SVON (Servo on) OFF.
Turn off the power of Driver Unit.