Appendix
— A-24 —
Appendix 7:
Wiring of RS-232C Communication Cable
If any terminal other than the NSK Handy Terminal FHT31 is used, follow the specifications of the higher level
control device for wiring the RS-232C communication cable.
Following examples shown in Figure A-24 and Figure A-25 are for the connection with a personal computer
compatible with DOS/V (D-sub 9 pins connector).
RTS control/CTS monitoring active (standard)
Fig A-22: Wiring example: With flow control
TXD
3
RXD
2
RTS
7
CTS
8
DSR
6
DTR
4
SG
5
FG
1
TXD
3
RXD
7
RTS
2
CTS
4
DSR
5
DTR
6
SG
9
FG
RS-232C terminal
EDC Driver Unit
CN1
RTS control/CTS monitoring inactive
Since this connection applies to non-procedural communication, the Driver Unit Model EDD may fail to
read data if a large amount of data is received too quickly. Make sure that the Driver Unit Model EDD
echoes back, or leave spaces between the data transmission.
Be sure to short the signals of RTS and CTS of the Driver Unit.
Otherwise the communication will be disabled.
Fig A-23: Wiring example: Without flow control
1
TXD
3
RXD
7
RTS
2
CTS
4
DSR
5
DTR
6
SG
9
FG
RS-232C terminal
EDC Driver Unit
CN1
TXD
3
RXD
2
RTS
7
CTS
8
DSR
6
DTR
4
SG
5
FG
Driver Unit Model EDD
Driver Unit Model EDD
Summary of Contents for EDD Megatorque Motor
Page 8: ... Blank Page ...
Page 146: ...6 Operation 6 38 Blank Page ...
Page 184: ...7 Operational Function 7 38 Blank Page ...
Page 211: ...8 More Advanced Function 8 27 ...
Page 246: ...8 More Advanced Function 8 62 Blank Page ...
Page 332: ...9 Details of Command and Parameter 9 86 Blank Page ...
Page 340: ...10 Maintenance 10 8 Blank Page ...