Appendix
— A-2 —
Monitor for Internal Recognition of Input and Output State: Monitor IO1
Monitors the applied state of following function to the control inputs and outputs: the polarity reverse and
the anti-chattering timer to the control inputs, and the stability timer for the control outputs.
For the inputs, the monitor reports how the Driver Unit recognizes the application state of
functions.
(The readout is the applied state of parameters AB [Input polarity] and NW [Anti-chattering
timer] in the command PI [Edit input port])
For the outputs, the monitor reports the state just before the application of output logic.
(The readout is the applied state of the parameters ST (Stability timer) in the command PO (Edit
control output). The parameter GC (Output logic) is not applied.)
Fig A-2: Example of Monitor IO1
IO1
GFEDCBA9876543210
00000000000000000
00000000000000000
State of input
Guide
State of output
0: Not functioning
1: Functioning
0: Not detected
1: Detected
The readout of the state of the input signals by the monitor IO1 will be affected by the parameter AB (Input
polarity).
For example, the shipping set of the input EMST (Emergency stop) is a normally closed contact.
As shown in Figure A-3 below, the function of emergency stop is effective even the input signal is
OFF at the moment of (1). At the moment of (2), the function of emergency stop is invalid when
the input signal is ON.
Fig A-3: Port polarity and ON/OFF of the input EMST
ON
OFF
Effective
Ineffective
Input EMST
Emergency stop function
(In case of a normally
closed contact)
(1)
(2)
The “Table A-2: Read out of the monitors IO0 and IO1 when the input EMST is a normally closed
contact” below shows the comparison of the readouts of the monitor IO0 and IO1 at the moment
of (1) and (2) in “Fig A-3: Port polarity and ON/OFF of the input EMST” above.
Table A-2: Read out of the monitors IO0 and IO1 when the input EMST is a normally closed contact
Moment
Monitor IO
Readout
G F E DC B A 9 8 7 6 5 4 3 2 1 0
(1)
IO0
0
IO1
1
(2)
IO0
1
IO1
0
Summary of Contents for EDD Megatorque Motor
Page 8: ... Blank Page ...
Page 146: ...6 Operation 6 38 Blank Page ...
Page 184: ...7 Operational Function 7 38 Blank Page ...
Page 211: ...8 More Advanced Function 8 27 ...
Page 246: ...8 More Advanced Function 8 62 Blank Page ...
Page 332: ...9 Details of Command and Parameter 9 86 Blank Page ...
Page 340: ...10 Maintenance 10 8 Blank Page ...