9. Details of Command and Parameter
— 9-49 —
P
MXY : Monitor Offset, Secondary
The parameter MXY sets the offset of a monitor output specified by the parameter MX.
Refer to “7.4.2. Customization of Monitor Data” for details.
Category
Parameter
Format
MXY data
Data range
Depends on the setting of parameter
MX.
Shipping set
0.000
MY : Motor Cycle Stop
The command MY causes the cycle stop of currently executing programmed operation.
The program processing stops at completion of program line currently executed
If the Motor is moving, it stops at its completion of the operation.
Category
Command
Format
MY
P
NA : Near A
The parameter sets a proximity distance to activate the output NEARA (Target proximity A).
Refer to “7.2.7. Target Proximity: NEARA and NEARB” for details.
In a positioning operation, the output NEARA closes when the Motor reaches to the point short from the
target position set by the parameter NA in units of pulse.
Category
Parameter
Format
NA data
Data range
0 to 2 62 144 000 [pulse]
Shipping set
0
P
NB : Near B
The parameter sets a proximity distance to activate the output NEARB (Target proximity A).
Refer to “7.2.7. Target Proximity: NEARA and NEARB” for details.
In a positioning operation, the output NEARB closes when the Motor reaches to the point short from the
target position set by the parameter NB in units of pulse.
Category
Parameter
Format
NB data
Data range
0 to 2 62 144 000 [pulse]
Shipping set
0
Summary of Contents for EDD Megatorque Motor
Page 8: ... Blank Page ...
Page 146: ...6 Operation 6 38 Blank Page ...
Page 184: ...7 Operational Function 7 38 Blank Page ...
Page 211: ...8 More Advanced Function 8 27 ...
Page 246: ...8 More Advanced Function 8 62 Blank Page ...
Page 332: ...9 Details of Command and Parameter 9 86 Blank Page ...
Page 340: ...10 Maintenance 10 8 Blank Page ...