8. More Advanced Function
— 8-16 —
8.3. Extended Control Output
8.3.1. In-zone Output: ZONEA, ZONEB, and ZONEC
The output reports that the Motor is in the predetermined zone.
Table 8-14: Signal logic of outputs of ZONEA, ZONEB and ZONEC
Logic
Description
Open
Out of the zone
Closed
In the specified zone, or assuring the minimum output
elapsing time.
Table 8-15: Parameter related to the outputs ZONEA, ZONEB and ZONEC
Signal name
(code)
Name
Initial
setting
Data range
Unit
ZAS
ZBS
ZCS
Start point of zone A
Start point of zone B
Start point of zone C
0
0 to 2 621 439
pulse
ZAE
ZBE
ZCE
End point of zone A
End point of zone B
End point of zone C
0
0 to 2 621 439
pulse
ZAW
ZBW
ZCW
Zone A stability timer
Zone B stability timer
Zone C stability timer
0.0
0.0 to 10 000.0
ms
The parameters ZAS (Start point of zone A) and ZAE (End point of zone A) set the zone. The zone starts
from the start point in the counting up direction of scale data and ends at the end point as shown in the
figure below.
The zones B and C can be set by the parameters ZBS, ZBE, ZCS and ZCE respectively in the
same way described above. .
Fig 8-6: Setting of zone A
Count up direction
Zone A
ZBE: End point of
zone A
Count up direction
ZBE: End point of
zone A
Zone A
In case of the paraemter DI0
In case of the paraemter DI1
ZAS: Start point of zone A
ZAS: Start point of zone A
領域
A
開始点
Summary of Contents for EDD Megatorque Motor
Page 8: ... Blank Page ...
Page 146: ...6 Operation 6 38 Blank Page ...
Page 184: ...7 Operational Function 7 38 Blank Page ...
Page 211: ...8 More Advanced Function 8 27 ...
Page 246: ...8 More Advanced Function 8 62 Blank Page ...
Page 332: ...9 Details of Command and Parameter 9 86 Blank Page ...
Page 340: ...10 Maintenance 10 8 Blank Page ...