11. Alarm and Warning
— 11-4 —
The table below lists the alarms and warnings that won’t be recorded to the alarm history.
Table 11-2: Alarms and warnin
gs that won’t be recorded to the alarm history
7 segments LED
Command TA: Tell alarm
Description
Motor
condition
C3
C3>CPU Error
CPU error
Servo-off
E0
E0>RAM Error
RAM error
E2
E2>ROM Error
ROM error
F2
F2>Software Over Travel
Software over travel limit is
activated.
Servo-lock
F3
F3>Hardware Over Travel
Hardware over travel limit is
activated
F4
F4>Emergency Stop
The input of EMST is ON.
Servo-off
P3
P3>Control AC Line Under
Voltage
Control power falls below the limit.
It may be recorded to the alarm history depending on the details of alarm.
When the home position is reset by the command AZ (Absolute ZERO position set) or the Home Return
operation, the event code “NO” is recorded: However this is not abnormal.
Refer to “7.3.2.2. Monitor for Alarm History and Event: Monitor TA/HI” for details.