8. More Advanced Function
— 8-35 —
If the function of shorter way positioning is not required, you can set the rotational direction to each
positioning command.
The Motor rotation is in the plus direction if “/PL” is specified such as “AD24000/PL.”
The Motor rotation is in the minus direction if “/MI” such as “AD24000/MI.”
Fig 8-16: Positioning with specified rotational direction
Current
position
Target
position
Plus direction
Target
position
Target
position
Minus
direction
Specified in the minus direction (/MI)
Specified in the plus direction (/PL)
Count up
Count up