![NSK EDD Megatorque Motor User Manual Download Page 274](http://html.mh-extra.com/html/nsk/edd-megatorque-motor/edd-megatorque-motor_user-manual_1714671274.webp)
9. Details of Command and Parameter
— 9-28 —
FR
: Feedback Signal Resolution
This parameter sets the resolution of the phase A and phase B of the position feedback signal.
Refer to “7.2.8. Position Feedback Signal” for details.
This will set the total number of edge count of the phase A and B pulses for one Motor
revolution
Category
Parameter
Format
FR data
Data range 1
0
: Output of the phases A and B of position feedback is OFF.
Data range 2
1 to 5 242 880
[count/revolution]
Shipping set
81 920
Setting of the parameter FR automatically sets the parameter VL (Velocity limiter).
The limitation on the velocity is to control the frequency of the position feedback signal not to
exceed 781 [kHz].
FRUN: Function RUN
This is to monitor the state of the input RUN (Positioning start).
Refer to “7.1.5. Program Start: RUN, Internal Program Channel Selection: Input PRG0 to
PRG7” for details.
The monitored state is after application of the parameters AB (Polarity) and NW (Anti-chattering timer) in
the command PI (Edit input port).
Category
Monitor
Format
FRUN
Data range
0
: OFF
1
: ON
P
FS
: Low-pass Filter, Secondary
Sets the low-pass filter to the torque command.
Refer to “8.5.2. Digital Filter” for details.
Category
Parameter
Format
FS data
Data range 1
0
: Secondary low-pass filter is OFF.
Data range 2
10 to 1000 [Hz]
Shipping set
0
This parameter will be automatically set by an execution of the command AT (Automatic tuning).
Summary of Contents for EDD Megatorque Motor
Page 8: ... Blank Page ...
Page 146: ...6 Operation 6 38 Blank Page ...
Page 184: ...7 Operational Function 7 38 Blank Page ...
Page 211: ...8 More Advanced Function 8 27 ...
Page 246: ...8 More Advanced Function 8 62 Blank Page ...
Page 332: ...9 Details of Command and Parameter 9 86 Blank Page ...
Page 340: ...10 Maintenance 10 8 Blank Page ...