4. RS-232C Communication and USB Communication
— 4-14 —
4.2.4.2.
Monitoring Parameters Altered from Shipping Set
When adjusting and setting parameters, you may read out parameter values only which have been altered
from the shipping set.
The command TS0 monitors all parameter values that belong to parameter groups of TS1 to TS12. Here,
let’s use the command TS (Tell settings) to read out the parameters which have been altered from the
shipping set.
Among all parameters that can be read out by the command TS0, let’s read out only the
parameters whose setting have been altered from the shipping set.
Enter as
TS
+
number
+
/MD
.
The parameters whose setting has been altered from the shipping set are identified. The prompt
“:” (colon) will appear on the screen to indicate the completion of readout.
4.2.5. Monitoring the Current Status
This function is useful when you need to monitor various conditions of the System in the middle of
condition adjustment.
The following example describes how to monitor the current position by the Monitor TP (Read out current
position [in units of pulse]).
Enter as
Monitor code
+
/RP
.
The current position is read out continuously. An input of the BS key will resume the readout
and the prompt changes to “:” (colon).