9. Details of Command and Parameter
— 9-35 —
P
GT : Switching Gain Timer
The parameter is the stability timer for position error to switch the gain in the automatic gain switching
function.
Refer to “8.5.4. Automatic Gain Switching” for details.
It switches the gain for Motor stationary level when the position error is less or equal to the setting of
parameter GP (Gain switching point) for a time set by the parameter GT.
Parameter
Parameter
Format
GT data
Data range
0.0 to 10 000.0 [ms]
Shipping set
0.0
P
HA : Home Return Acceleration
Sets the acceleration for Home Return operation.
Refer to “8.8. Home Return” for details.
Category
Parameter
Format
HA data
Data range
0.1 to 800.0 [s
-2
]
Shipping set
1.0
P
HB : Home Return Deceleration
Sets the deceleration for Home Return.
Refer to “8.8. Home Return” for details.
Category
Parameter
Format
HB data
Data range 1
0.0
: Use the same value as the parameter HA.
Data range 2
0.1 to 800.0 [s
-2
]
Shipping set
0.0
P
HD : Home Return Direction
Sets the direction of Home Return.
Refer to “8.8. Home Return” for details.
Category
Parameter
Format
HD data
Data range
0
: Home Return starts in the plus direction
1
: Home Return starts in the minus direction
Shipping set
1
Setting of the parameter HD will be effective for the next Home Return operation.
Summary of Contents for EDD Megatorque Motor
Page 8: ... Blank Page ...
Page 146: ...6 Operation 6 38 Blank Page ...
Page 184: ...7 Operational Function 7 38 Blank Page ...
Page 211: ...8 More Advanced Function 8 27 ...
Page 246: ...8 More Advanced Function 8 62 Blank Page ...
Page 332: ...9 Details of Command and Parameter 9 86 Blank Page ...
Page 340: ...10 Maintenance 10 8 Blank Page ...