8. More Advanced Function
— 8-12 —
8.2. Extended Control Input
8.2.1. Input HOLD: HLD
This input pauses the operation caused by an internal command. Deactivation of the input HOLD starts the
operation again.
Table 8-7: Signal logic of input HLD
Logic
Description
OFF
Deactivates the signal.
ON
Starts deceleration and stops operation.
When the HLD input is turned ON in the middle of operation caused by an internal command, such as
positioning command, jogging and Home Return, the Motor decelerates with the deceleration rate
specified in the operation program, then stops.
This input is not effective for the pulse train command.
If the input is turned ON in the middle of setting a parameter to a program, the Driver Unit
completes the setting of the program line, then holds operation.
While the operation is being hold, the Driver Unit holds operation caused by an internal command or
execution of a program. However the output BUSY (In-operation) remains closed.
The held operation starts again when the input HLD is OFF. If the operation involves rotation of the
Motor, the Motor accelerates again.
Occurrence of an alarm and activation of the input STP (Stop) signal cancels the holding state
and the output BUSY opens. In such state, deactivation of the input HLD does not start the
operation again.
The output BUSY closes and the operation remains held while the input HLD is being ON, even the input
RUN (Start program) or the operation command is inputted.
Fig 8-2: Signal timing of the input HLD (Internal command)
Motor motion
MA
ON
OFF
Velocity in
CW or CCW
closed
open
Max. 2 ms .
ON
OFF
Input HLD
Input RUN
closed
open
Output BUSY
closed
open
Output IPOS
(FW
>0: FIN
)
Max. 0.5 ms
Max. 0.5 ms
Output IPOS
(FW<
0: CFIN)
(FW =
0: IPOS
)
Max. 2 ms.
MB
B
MB
B
MA
FW
value
In-position
Closed when the target position data is held.
Opens when the target position data is lost.
Rest of rotation amount
Max. 1 ms
Summary of Contents for EDD Megatorque Motor
Page 8: ... Blank Page ...
Page 146: ...6 Operation 6 38 Blank Page ...
Page 184: ...7 Operational Function 7 38 Blank Page ...
Page 211: ...8 More Advanced Function 8 27 ...
Page 246: ...8 More Advanced Function 8 62 Blank Page ...
Page 332: ...9 Details of Command and Parameter 9 86 Blank Page ...
Page 340: ...10 Maintenance 10 8 Blank Page ...