6. Operation
— 6-35 —
6.3.6.3.
Analog Input Operation
In the velocity control mode and torque control operation, the Motor rotational velocity and output torque
can be directly controlled by the analog input command input.
Analog command voltage range is ± 10 [VDC]. Setting of the parameter AF enables offset tuning. For
details, refer to “6.3.6.4 Analog Command Input Offset.”
The polarity of command voltage can be selected by the parameter AC for analog command input
selection. Refer to “Table 6-15: Analog input operation, rotational direction” for the setting regarding the
polarity and rotational direction of the command.
The relationship between the command voltage, and the rotational velocity and output torque can be
changed by the parameter AG for analog command gain. Refer to “Fig 6-25: Command voltage, and
Motor velocity and output torque
(AC1 and DI0)” for command voltage and rotational velocity.
Table 6-15: Analog input operation, rotational direction
DI
AC
Command
voltage
Motor rotational
direction
0
1
+
CW
0
1
-
CCW
0
-1
+
CCW
0
-1
-
CW
1
1
+
CCW
1
1
-
CW
1
-1
+
CW
1
-1
-
CCW
Fig 6-25: Command voltage, and Motor velocity and output torque
(AC1 and DI0)
- 10 V
Relationship between command
voltage and rotational velocity
Relationship between command
voltage and output torque
+ 10 V
-10s
-1
10s
-1
AG = 0.5
AG = 1.0
AG = 2.0
Input
voltage
Rotational velocity
- 10 V
+ 10 V
100
%
-100
%
Output torque
Input
voltage
Input
voltage
!
Caution
• The rotational velocity of the Motor is limited depending on the Motor type.
• When using the Motor with the maximum rotational velocity less than 10
[s
-1
], tune the parameter AG for analog command gain so that the
rotational velocity does not exceed the maximum rotational velocity.
Summary of Contents for EDD Megatorque Motor
Page 8: ... Blank Page ...
Page 146: ...6 Operation 6 38 Blank Page ...
Page 184: ...7 Operational Function 7 38 Blank Page ...
Page 211: ...8 More Advanced Function 8 27 ...
Page 246: ...8 More Advanced Function 8 62 Blank Page ...
Page 332: ...9 Details of Command and Parameter 9 86 Blank Page ...
Page 340: ...10 Maintenance 10 8 Blank Page ...