9. Details of Command and Parameter
— 9-48 —
MW : Main Power Supply Internal Voltage Monitor
Monitors the internal direct current voltage after commutation of the main power.
Category
Monitor
Format
MW data
Data range
0.0 to 401.3 [v]
P
MX : Monitor, Secondary
Sets an item to be monitored by the MON2 (Analog monitor, secondary)
Refer to ”7.4. Analog Monitors” for details.
Category
Parameter
Format
MX data
Data range 1
0
1
2
3
4
5
6
7
8
: Current velocity
: Commanded velocity
: Velocity error
: Torque command
: øU current
: Transient position command
: Residual pulses in the error counter (Zoomed)
: Residual pulses in the error counter (Normal)
: Software thermal loading
Data range 2
Command
name
: Specify a monitor name, such as
“MXTV”
, for monitoring.
Shipping set
0
A change of this parameter will automatically reset the parameters MXY (Monitor offset, secondary) and
MXR (Monitor range, secondary) in accordance with the specified monitor.
The output offset of parameter MXY is set to a value when the monitor center is set to 2.5 [V].
The output range of parameter MXR is set to a value when the maximum monitor output is 5.0
[V].
P
MXR: Monitor Range, Secondary
This parameter specifies the monitor output range of the parameter MX (Analog monitor, secondary).
Refer to “7.4.2. Customization of Monitor Data” for details.
Category
Parameter
Format
MXR data
Data range
(Depends on the setting of the monitor
MX.)
Shipping set
10.000
Summary of Contents for EDD Megatorque Motor
Page 8: ... Blank Page ...
Page 146: ...6 Operation 6 38 Blank Page ...
Page 184: ...7 Operational Function 7 38 Blank Page ...
Page 211: ...8 More Advanced Function 8 27 ...
Page 246: ...8 More Advanced Function 8 62 Blank Page ...
Page 332: ...9 Details of Command and Parameter 9 86 Blank Page ...
Page 340: ...10 Maintenance 10 8 Blank Page ...