4.4
Using the Sequence Function
EC1000SA
4-25
An example of basic step transitions is shown below.
<START>
Output parameters
Time
Normal output
step
Step 1
Step 2
Step 3
Steps 1, 2
Step 3
Figure 4-5. Example of Basic Step Transitions
c) Sequence mode
Figure 4-6
shows a mode transition diagram for sequence operations.
Idle mode
(normal output)
Output on
Run mode
(sequence
execution)
Hold mode
(pause)
<Start>
<Stop>
<Stop>
<Hold>
<Start>
Figure 4-6. Block Diagram of Sequence Mode Transitions
-----------
Notes
-----------------------------------------------------------------------------------------------------
Modes also change according to the [step end] specification.
-----------------------------------------------------------------------------------------------------------------------------
Table4-6.
Sequence Modes
Idle mode
Mode during normal output.
Run mode
Mode during sequence execution.
Hold mode
Sequence pause mode.
Maintains output at time when <Hold> was set.