![NF EC1000SA Instruction Manual Download Page 221](http://html1.mh-extra.com/html/nf/ec1000sa/ec1000sa_instruction-manual_1684880221.webp)
6.3
Command Descriptions
EC1000SA
6-43
SYSTem:ERRor?
This reads one error from the error queue (FIFO), and clears the read error in the error queue. The
maximum number of errors that can be held in the error queue is 20. If 21 or more errors occur,
[
−
350, “Too Many Errors”] is inserted as the 20th error.
Syntax:
SYSTem:ERRor?
Parameters:
None
Query example:
SYST:ERR?
Response format:
<NR1>,<SRD>
Response example:
0, “No error”
SYSTem:PON[:OUTPut]
This sets the output status at power-on. When the output status is on at power-on, the output turns
on after the start-up and its display finishes.
However, if the system is restarted after a problem has been detected and the system has been
locked, it will be started with output off regardless of this setting.
Syntax:
SYSTem:PON[:OUTPut]
<bool>
Parameters:
OFF | 0 / ON | 1
Command example:
SYST:PON OFF
Query example:
SYST:PON?
Response format:
<NR1>
Response example:
0
SYSTem:TUNit
This sets the sequence step execution time unit as s or ms.
Syntax:
SYSTem:TUNit
<NR1>
Parameters:
0 (s) / 1 (ms)
Command example:
SYST:TUN 0
Query example:
SYST:TUN?
Response example:
0
Summary of Contents for EC1000SA
Page 1: ...NF Corporation PROGRAMMABLE AC DC POWER SOURCE EC1000SA Instruction Manual nbn Austria GmbH...
Page 2: ...DA00036667 003 PROGRAMMABLE AC DC POWER SOURCE EC1000SA Instruction Manual...
Page 236: ...6 9 Notes on Remote Control EC1000SA 6 58...
Page 260: ...8 5 Backup Battery EC1000SA 8 8...
Page 280: ...9 17 External Dimensions and Weight EC1000SA 9 20...