![NF EC1000SA Instruction Manual Download Page 242](http://html1.mh-extra.com/html/nf/ec1000sa/ec1000sa_instruction-manual_1684880242.webp)
7.2
Error Messages and Error Handling
EC1000SA
7-6
7.2.2 Protection function-related errors
When a protection function-related error has occurred, an error message is displayed in the message
window, and operation is stopped.
Figure 7-2. Screen Display When Protection Function-Related Error Has Occurred
When a protection function-related error message is displayed, turn off the power switch. (
See “7.1
Protection Function”
.
)
Table7-3
lists error messages and actions when errors are detected.
Table7-3. Protection Function-Related Errors
Error Message
Protection Item
Cause and Operation or Action Required
When Fault Is Detected
System Locked.
caused by:
COMMUNICATION FAILURE 1
Internal
communication
error 1
Output is set to off and system lock status is
set. Turn off the power switch.
If the same protection error occurs again after
the power is turned back on, contact NF
Corporation or our agent.
System Locked.
caused by:
COMMUNICATION FAILURE 2
Internal
communication
error 2
System Locked.
caused by:
FRONT PANEL FAILURE
Control panel
error
System Locked.
caused by:
AMP NO RESPONSE ERROR
AMP no response
error
System Locked.
caused by:
FAN FAILURE ERROR
Fan failure error
Summary of Contents for EC1000SA
Page 1: ...NF Corporation PROGRAMMABLE AC DC POWER SOURCE EC1000SA Instruction Manual nbn Austria GmbH...
Page 2: ...DA00036667 003 PROGRAMMABLE AC DC POWER SOURCE EC1000SA Instruction Manual...
Page 236: ...6 9 Notes on Remote Control EC1000SA 6 58...
Page 260: ...8 5 Backup Battery EC1000SA 8 8...
Page 280: ...9 17 External Dimensions and Weight EC1000SA 9 20...