![NF EC1000SA Instruction Manual Download Page 239](http://html1.mh-extra.com/html/nf/ec1000sa/ec1000sa_instruction-manual_1684880239.webp)
7.1
Protection Function
EC1000SA
7-3
Table7-1. Protection Function
Protection
Action When Detected
Displayed Message
Output off
System
Lock
Internal
communication error
1
√
√
Internal communication error message 1
See
“
7.2.2 Protection function-related
errors
”
.
Internal
communication error
2
√
√
Internal communication error message 2
See “7.2.2 Protection function-related
errors
”
.
Control panel error
√
√
Control panel error message
See “7.2.2 Protection function-related
errors
”
.
AMP no response
error
√
√
AMP no response error message
See
“
7.2.2 Protection function-related
errors
”
.
Fan failure error
√
√
Fan failure error message
See
“
7.2.2 Protection function-related
errors
”
.
Output overvoltage
error
√
Output overvoltage error message
See “7.2.4 Warning messages”
.
Output RMS current
error
√
Output RMS current error message
See “7.2.4 Warning messages
”
.
Output peak current
error
√
Output peak current error message
See “7.2.4 Warning messages”
.
DC overvoltage error
√
DC overvoltage error message
See “7.2.4 Warning messages”
.
DC undervoltage
error
√
∆
Note
DC undervoltage error message
See “7.2.4 Warning messages”
.
Abnormal internal
temperature
√
Internal temperature warning message
See “7.2.4
Warning messages”
.
External sync signal
frequency range error
√
External sync signal frequency range warning message
See “7.2.4 Warning messages”
.
Note
System lock may occur.
Summary of Contents for EC1000SA
Page 1: ...NF Corporation PROGRAMMABLE AC DC POWER SOURCE EC1000SA Instruction Manual nbn Austria GmbH...
Page 2: ...DA00036667 003 PROGRAMMABLE AC DC POWER SOURCE EC1000SA Instruction Manual...
Page 236: ...6 9 Notes on Remote Control EC1000SA 6 58...
Page 260: ...8 5 Backup Battery EC1000SA 8 8...
Page 280: ...9 17 External Dimensions and Weight EC1000SA 9 20...