![NF EC1000SA Instruction Manual Download Page 203](http://html1.mh-extra.com/html/nf/ec1000sa/ec1000sa_instruction-manual_1684880203.webp)
6.3
Command Descriptions
EC1000SA
6-25
Fourth parameter (AC voltage operation type)
Type
<NR1>
Range
0 (CONST), 1 (KEEP), or 2 (SWEEP)
Fifth parameter (frequency)
Type
<NR2>
Range
1.0 to 550.0
Sixth parameter (frequency operation type)
Type
<NR1>
Range
0 (CONST), 1 (KEEP), or 2 (SWEEP)
Seventh parameter (waveform)
*The unit for the third parameter AC voltage varies depending on the seventh parameter setting.
Type
<NR1>
Range
0 (SIN), 1 (SQU), or 2 to 17 (ARB1 to ARB16)
Eighth parameter (waveform operation type)
Type
<NR1>
Range
0 (CONST) or 1 (KEEP)
Ninth parameter (start phase)
Type
<NR2>
Range
0.0 to 359.9
10th parameter (start phase operation)
Type
<NR1>
Range
0 (CONST) or 1 (KEEP)
11th parameter (step synchronized output)
Type
<NR1>
Range
0 (LL), 1 (LH), 2 (HL), or 3 (HH)
12th parameter (step synchronized output operation type)
Type
<NR1>
Range
0 (CONST) or 1 (KEEP)
Command example: SEQ:EPAR 0, 0, 100.0, 0, 50.0, 0, 1, 0, 90.0, 0, 0, 0
Query example:
SEQ:EPAR?
Response example:
0, 0, 100.0, 0, 50.0, 0, 1, 0, 90.0, 0, 0, 0
Summary of Contents for EC1000SA
Page 1: ...NF Corporation PROGRAMMABLE AC DC POWER SOURCE EC1000SA Instruction Manual nbn Austria GmbH...
Page 2: ...DA00036667 003 PROGRAMMABLE AC DC POWER SOURCE EC1000SA Instruction Manual...
Page 236: ...6 9 Notes on Remote Control EC1000SA 6 58...
Page 260: ...8 5 Backup Battery EC1000SA 8 8...
Page 280: ...9 17 External Dimensions and Weight EC1000SA 9 20...