6.3
Command Descriptions
EC1000SA
6-46
∗∗∗∗
IDN?
T
his returns the model name, etc. The response message includes the “manufacturer, model name,
serial number, and firmware version”.
Syntax:
∗
IDN?
Parameters:
None
Query example:
∗
IDN?
Response format:
<SRD>
Response example:
“NF Corporation, EC1000SA, 000001, Ver1.00”
∗∗∗∗
OPC
When all operations
※
have been completed, this sets the standard event register OPC bit (BIT0).
∗
OPC? returns 1 when all operations have been completed. However, the standard event register
OPC bit is not cleared to zero when
∗
OPC? is executed.
Syntax:
∗∗∗∗
OPC
Parameters:
None
Command example:
∗
OPC
Query example:
∗
OPC?
Response format:
<NR1>
Response example:
1
∗∗∗∗
RCL
This recalls status information stored to memory by
∗
SAV. The selection range for the recall
memory is 1 to 30. However, recall is disabled when output is on. ([1, “Invalid with output on”]
error occurs.)
Syntax:
∗∗∗∗
RCL
<NR1>
Parameters:
1 to 30
Command example:
∗
RCL 1
Response format:
None
Response example:
None
Summary of Contents for EC1000SA
Page 1: ...NF Corporation PROGRAMMABLE AC DC POWER SOURCE EC1000SA Instruction Manual nbn Austria GmbH...
Page 2: ...DA00036667 003 PROGRAMMABLE AC DC POWER SOURCE EC1000SA Instruction Manual...
Page 236: ...6 9 Notes on Remote Control EC1000SA 6 58...
Page 260: ...8 5 Backup Battery EC1000SA 8 8...
Page 280: ...9 17 External Dimensions and Weight EC1000SA 9 20...