CORRECTIVE MAINTENANCE
5-45
iPASOLINK EX Advanced: O
PERATION
& M
AINTENANCE
GGS-000548-01E
Equipment
This condition indicates that the temperature within equipment exceeds the
operational limitation.
Procedure 5-33
1.
Check the room temperature, and adjust it.
2.
Retrieve the
Current Status
, and check if the
Temperature
alarm is cleared.
NOTE:
Wait at least for an hour in the adjusted air before checking the
Current Status
.
If the alarm is not cleared, contact NEC for the further maintenance support.
This step ends the procedure.
BB
This condition is not an alarm. The message informs that the Dynamic Entry in L2
Switch has reached the maximum number.
MODEM
This condition is not an alarm. The message indicates the state of Trap Suppression
function.
MODEM
This condition is not an alarm. The message informs that the modulation system of
MODEM at the transmitting side has been changed.
Temperature
Total FDB Full
Trap Suppression Status
TX Modulation