4-26
CONTROL ITEMS
GGS-000548-01E
iPASOLINK EX Advanced: Operation & Maintenance
4.4.5.2
Switch Timing Sources
Procedure 4-9
1. Launch and log in to
WebLCT
.
2. Click the
Maintenance
button on the top of the
WebLCT
window to switch the
state to the maintenance mode. See
4.2.1 Change to Maintenance Mode (for
for operating steps.
3. In the
MENU
frame on the left, expand
Maintenance Control
, then its
submenu
Protection Control
to select
Timing Source Switch Control
. The
Timing Source Switch Control
window appears.
4. Click a link in the Timing Source SW Control fields:
NOTE:
The target object must NOT be in the Lockout mode.
Figure 4-38 Timing Source Switch Control Window
5.
Timing Source Switch Control
option window appears.
Select a switching
mode (
Manual SW
or
Forced SW
), then click the
OK
button.
Figure 4-39 Timing Source Switch Control Option Window
Warning
dialog box appears.
click