Assign Alarm/AIS Settings
10-5
iPASOLINK EX Advanced:
S
ET
N
ETWORK
AND
S
YSTEM
P
ROVISIONING
GGS-000547-01E
Figure 10-6 Alarm Severity Setting Option Window (Example: RF)
Table 10-2 Alarm Status Values (Severity Levels)
Parameter
Value
Description (Intended Condition)
(Alarm Item)
Critical
A service-affecting condition that requires an immediate corrective
action.
Major
A service-affecting condition that requires an urgent corrective action.
Minor
An existence of non-service-affecting failure that should take a
corrective action to prevent more serious service-affecting failure.
Warning
A potential or impending service affecting failure. Action should be
taken to further diagnose (if necessary), and correct the problem in
order to prevent more serious service affecting failure.
Table 10-3 Alarm Severity Setting — RF
RF Alarm Item
Default State
Your Assignment
TX Power
Major
RX Level
Major
Table 10-4 Alarm Severity Setting — MODEM (1 of 2)
MODEM Alarm Item
Default State
Your Assignment
LOF
Major
Frame ID
Major
High BER
Major
Low BER
Minor
Early Warning
Warning
RDI
Warning
UAE
Warning
AMBR Range Mismatch
Major
Summary of Contents for iPASOLINK EX Advanced
Page 29: ...2 8 END COMPOSITIONS GGS 000546 01E iPASOLINK EX Advanced INSTALLATION ...
Page 77: ...GGS 000547 01E GGS 000547 01E Printed in Japan 2016 by NEC Corporation ...
Page 87: ... x END CONTENTS GGS 000547 01E This page is intentionally left blank ...
Page 581: ...GGS 000548 01E GGS 000548 01E Printed in Japan 2016 by NEC Corporation ...
Page 775: ...GGS 000549 01E GGS 000549 01E Printed in Japan 2016 by NEC Corporation ...
Page 791: ...GGS 000552 01E GGS 000552 01E Printed in Japan 2016 by NEC Corporation ...