CORRECTIVE MAINTENANCE
5-39
iPASOLINK EX Advanced: O
PERATION
& M
AINTENANCE
GGS-000548-01E
Equipment
This condition indicates that the system detects the equipment failure in the BB
section. If this alarm occurs, contact NEC for the further maintenance support.
RF
This condition is not an alarm. The message indicates if the RF TX Power Output is
set to
Mute
or not.
Equipment
This condition is not an alarm. The message shows the PTP Clock of the equipment.
Equipment
This condition is not an alarm. The message indicates the level of PTP Clock Quality.
MODEM
This condition indicates that the settings of PTP Mode at two opposing NEs do no
match.
Procedure 5-25
1.
Check the settings of following:
.Check and adjust the PTP Mode settings of both local NE and its opposing
NE.
Check and adjust the Equipment Clock settings of both local NE and its
opposing NE
2.
Retrieve the
Current Status
, and check if the
PTP Mode Setting Mismatch
alarm is cleared. If the alarm is not cleared, contact NEC for the further
maintenance support.
This step ends the procedure.
Module-BB
Mute Status
Own Clock ID
PTP Clock Quality Level
PTP Mode Setting Mismatch
Summary of Contents for iPASOLINK EX Advanced
Page 29: ...2 8 END COMPOSITIONS GGS 000546 01E iPASOLINK EX Advanced INSTALLATION ...
Page 77: ...GGS 000547 01E GGS 000547 01E Printed in Japan 2016 by NEC Corporation ...
Page 87: ... x END CONTENTS GGS 000547 01E This page is intentionally left blank ...
Page 581: ...GGS 000548 01E GGS 000548 01E Printed in Japan 2016 by NEC Corporation ...
Page 775: ...GGS 000549 01E GGS 000549 01E Printed in Japan 2016 by NEC Corporation ...
Page 791: ...GGS 000552 01E GGS 000552 01E Printed in Japan 2016 by NEC Corporation ...