CONTROL ITEMS
4-31
iPASOLINK EX Advanced: O
PERATION
& M
AINTENANCE
GGS-000548-01E
4. Set the appropriate values, then click the
OK
button.
Figure 4-44 MODEM Maintenance Control Option Window
5.
Warning
dialog box appears.
Click the
OK
button.
Figure 4-45 Warning Dialog Box
6.
Information
dialog box appears. Click the
OK
button.
Figure 4-46 Information Dialog Box
The
MODEM Maintenance Control
window updates the information.
Table 4-3 ATPC Manual Control
Parameter
Value
Description
ATPC Manual Control
On
Enable/Disable ATPC Manual Control.
Off
ATPC Manual Power
–1.0
to
10.0
Set the transmit power value. [unit: dBm]