4-16
CONTROL ITEMS
GGS-000548-01E
iPASOLINK EX Advanced: Operation & Maintenance
5. Specify the following:
Figure 4-21 ERP Control Option Window
Select the operation type from the
Manual Control
drop-down list.
Assign a blocking port.
6. When completed, click the
OK
button of the option window.
7.
Warning
dialog box appears. Click the
OK
button to proceed.
Figure 4-22 Warning Dialog Box
Table 4-2 ERP Control Parameters
Parameter
Value
Description
Manual Control
Forced SW
Executes switching operation forcibly.
Manual SW
Executes switching operation according to the condition’s priority.
Clear
Clears the status placed by the executed command.
Block Port
Ring Port 0
Assigns a blocking port in the Ring.
Ring Port 1
Manual Control
drop-down list and
Block Port
radio buttons