CONTROL ITEMS
4-49
iPASOLINK EX Advanced: O
PERATION
& M
AINTENANCE
GGS-000548-01E
5.
Warning
dialog box appears. Click the
OK
button.
Figure 4-74 Warning Dialog Box
6.
Information
dialog box appears. Click the
OK
button.
Figure 4-75 Information Dialog Box
7.
The
Laser Shutdown Control
window updates the information.
Verify the
displayed parameters.
Figure 4-76 Laser Shutdown Control
8. When confirmed, click the
Maintenance
tool button on the
WebLCT
tool bar to
exit from the Maintenance Mode.
9. Confirm that the
MAINT
indicator on the tool bar changes from orange to
white. This step ends the procedure.
Table 4-9 ALS Restart
Parameter
Value
Description
ALS Restart
2s
Forcibly issues the optical output for 2 seconds where the
ALS (Automatic Laser Shutdown) is executed.
90s
Forcibly issues the optical output for 90 seconds where the
ALS (Automatic Laser Shutdown) is executed.