CONNECT CABLES
5-1
iPASOLINK EX Advanced:
I
NSTALLATION
GGS-000546-01E
5. CONNECT CABLES
5.1 Overview
This section provides the descriptions for connecting Traffic Cables and Power
Cable. This section also provides the assembly methods of the Grounding Cable and
Power cable for the purpose of preparing them on site if needed.
Following shows the summary of the cable installation:
1.
Connect the Grounding Cable to Grounding Terminal on iPASOLINK EX/A. (See
for detailed descriptions and steps.)
NOTE:
Tightening torque is 2.7 ±0.3 N•m
2.
Connect the Power Cable.
NOTE:
This step is not required when using a PoE. Go to
3.
Connect a LAN Cable to
DCN (PoE)
Port.
NOTE:
To use this port as the PoE, confirm that the power injector to be
connected is powered off. If it is powered on, connecting the LAN
cable to
DCN (PoE)
port immediately turns on the iPASOLINK EX/A.
(1) Connect a LAN Cable to
DCN (PoE)
Port on iPASOLINK EX/A.
(2) Connect the other end of LAN Cable:
To use this port as PoE, connect it to the power injector.
To operate
WebLCT
, connect it to your PC (web browser must be installed).
4.
Connect LAN Cables to
P2
and
P3
Ports, as necessary.
Summary of Contents for iPASOLINK EX Advanced
Page 29: ...2 8 END COMPOSITIONS GGS 000546 01E iPASOLINK EX Advanced INSTALLATION ...
Page 77: ...GGS 000547 01E GGS 000547 01E Printed in Japan 2016 by NEC Corporation ...
Page 87: ... x END CONTENTS GGS 000547 01E This page is intentionally left blank ...
Page 581: ...GGS 000548 01E GGS 000548 01E Printed in Japan 2016 by NEC Corporation ...
Page 775: ...GGS 000549 01E GGS 000549 01E Printed in Japan 2016 by NEC Corporation ...
Page 791: ...GGS 000552 01E GGS 000552 01E Printed in Japan 2016 by NEC Corporation ...