CORRECTIVE MAINTENANCE
5-25
iPASOLINK EX Advanced: O
PERATION
& M
AINTENANCE
GGS-000548-01E
Equipment
This condition is not an alarm. The message indicates the current state of PTP logical
ports.
MODEM
This condition indicates that the system detects degradation of radio signals. (Early
Warning threshold detection.)
Procedure 5-5
1.
Launch the WebLCT.
2.
Display the
Current Metering
to check
RX Level
.
If the value is appropriate, replace the equipment.
If the value is inappropriate, proceed with the flowchart:
.
This step ends the procedure.
Equipment
This condition is not an alarm. The system reports that the equipment starts up, and
the cause to start up or reboot.
ETH
This condition indicates that the 10G Ethernet Port on the local NE fails.
Procedure 5-6
1.
Check that the Ethernet Cable connected to the target port is appropriately
connected.
2.
Retrieve the
Current Status
, and check if the
ETH LF
alarm is cleared.
3.
Is
ETH LF
alarm cleared?
YES:
This step ends the procedure.
NO:
Replace the cable, then proceed to the next step.
Current Status
Early Warning
Equipment Start-up Status
ETH LF
Summary of Contents for iPASOLINK EX Advanced
Page 29: ...2 8 END COMPOSITIONS GGS 000546 01E iPASOLINK EX Advanced INSTALLATION ...
Page 77: ...GGS 000547 01E GGS 000547 01E Printed in Japan 2016 by NEC Corporation ...
Page 87: ... x END CONTENTS GGS 000547 01E This page is intentionally left blank ...
Page 581: ...GGS 000548 01E GGS 000548 01E Printed in Japan 2016 by NEC Corporation ...
Page 775: ...GGS 000549 01E GGS 000549 01E Printed in Japan 2016 by NEC Corporation ...
Page 791: ...GGS 000552 01E GGS 000552 01E Printed in Japan 2016 by NEC Corporation ...