This condition indicates that the system detects LTI (Loss of Timing Inputs) where
the equipment does not synchronize with any reference sources. The problem of this
condition pertains to the optical fiber cables, electrical cables, or to the far-end NE.
Procedure 5-23
1.
Check if any alarm regarding the reference clock occur. If any exist(s), clear it/
them.
2.
Retrieve the
Current Status
, and check if the
LTI
alarm is cleared. If the alarm is
not cleared, contact NEC for the further maintenance support.
This step ends the procedure.
Equipment
This condition is not an alarm. When the
Maintenance
indicates
On
, the system is
set into the Maintenance mode.
ETH
This condition is not an alarm. The message shows the operating type (MDI or MDI-
X) of the indicated Ethernet port currently running.
MODEM
BB
RF
This condition indicates that the system detects the hardware error of the indicated
object.
Procedure 5-24
1.
Replace the object.
2.
Retrieve the
Current Status
, and check if the
Module
alarm is cleared. If the
alarm is not cleared, contact NEC for the further maintenance support.
This step ends the procedure.
LTI
Maintenance
MDI/MDI-X
Module
Summary of Contents for iPASOLINK EX Advanced
Page 29: ...2 8 END COMPOSITIONS GGS 000546 01E iPASOLINK EX Advanced INSTALLATION ...
Page 77: ...GGS 000547 01E GGS 000547 01E Printed in Japan 2016 by NEC Corporation ...
Page 87: ... x END CONTENTS GGS 000547 01E This page is intentionally left blank ...
Page 581: ...GGS 000548 01E GGS 000548 01E Printed in Japan 2016 by NEC Corporation ...
Page 775: ...GGS 000549 01E GGS 000549 01E Printed in Japan 2016 by NEC Corporation ...
Page 791: ...GGS 000552 01E GGS 000552 01E Printed in Japan 2016 by NEC Corporation ...