ADJUST ANTENNA ANGLE
8-3
iPASOLINK EX Advanced:
I
NSTALLATION
GGS-000546-01E
CAUTION:
Surface of iPASOLINK EX/A may be hot during the operation.
Ensure not to touch the equipment by mistake.
(1) Remove a protective cap from
RSL
terminal on iPASOLINK EX/A, and
connect it to a digital multimeter using the lead between.
(2) Monitor levels at both the local and opposing site, and fix the reception
level to its maximum by turning iPASOLINK EX/As up and down and/or
left to right.
NOTES:
1.
RSL
monitor conforms to IEC61169-24.
2.
When the checks are done, put the waterproofing cap on to the
RSL
terminal to protect it.
Figure 8-3 Example to Measure Levels for Fixing Angles
Following shows the relationship between
RX INPUT LEVEL
and
RSL (V)
.
RSL TERMINAL
DIGITAL MULTIMETER
iPASOLINK EX/A