CONNECT CABLES
5-23
iPASOLINK EX Advanced:
I
NSTALLATION
GGS-000546-01E
5.8.2.3 Procedure
1.
Strip the cable jacket.
2.
Remove the insulation to expose each conductor:
NOTE:
Ensure not to damage the braided wire.
3.
Set contact to each conductor.
4.
Seal the crimp.
Tools
•
knife
•
cutter
•
measuring tool, etc.
5.75 ±0.25 mm