5-42/END
CORRECTIVE MAINTENANCE
GGS-000548-01E
iPASOLINK EX Advanced: O
PERATION
& M
AINTENANCE
ETH
This condition is not an alarm. The system detects that an
Errored Frame Seconds
Summary
message is issued at the opposing site.
ETH
This condition is not an alarm. The system detects that an
Errored Symbol Period
message is issued at the opposing site.
ETH
This condition indicates that Ethernet link failure at the opposing site is detected via
the incoming port. This is an alarm regarding IEEE802.3ah, Link OAM.
Procedure 5-29
1.
Check if any alarms occur to the equipment or cable connections at n the
opposing site, and if any exist, clear them.
2.
Retrieve the
Current Status
, and check if the
Remote Link Fault
alarm is
cleared. If the alarm is not cleared, contact NEC for the further maintenance
support.
This step ends the procedure.
RF
This condition indicates that the receiving level is lower than the threshold level
(between –72 to –94 dBm according to the modulation system and bit rates).
Procedure 5-30
for the procedure.
Remote Errored Frame Seconds Summary
Remote Errored Frame Symbol Period
Remote Link Fault
RX Level
Summary of Contents for iPASOLINK EX Advanced
Page 29: ...2 8 END COMPOSITIONS GGS 000546 01E iPASOLINK EX Advanced INSTALLATION ...
Page 77: ...GGS 000547 01E GGS 000547 01E Printed in Japan 2016 by NEC Corporation ...
Page 87: ... x END CONTENTS GGS 000547 01E This page is intentionally left blank ...
Page 581: ...GGS 000548 01E GGS 000548 01E Printed in Japan 2016 by NEC Corporation ...
Page 775: ...GGS 000549 01E GGS 000549 01E Printed in Japan 2016 by NEC Corporation ...
Page 791: ...GGS 000552 01E GGS 000552 01E Printed in Japan 2016 by NEC Corporation ...