CONNECT CABLES
5-9
iPASOLINK EX Advanced:
I
NSTALLATION
GGS-000546-01E
4.
Push the Bushing fully into the barrel:
Figure 5-12 Set Bushing into Barrel
Figure 5-13 Set Waterproofing Cap (1/2)
5.
Tighten the Gland Nut at the barrel end level, and secure them using the torque
wrench.
Figure 5-14 Secure Gland Nut
CAUTION:
In case using the thin cable, the Gland Nut may not stop and be secured at
the appropriate position if tightening it by force. Ensure that the barrel end does not
stick out of the gap at the Gland Nut end.
This step ends the procedure.
BUSHING
WITH RIB
Check that the bushing is fully inserted
within the barrel end.
BARREL
(GLAND NUT)
RIB
GLAND NUT