VX150 TO VX2 OPERATIONS & MAINTENANCE MANUAL
OPERATING THE TRANSMITTER
PAGE 2.2.130
VERSION 1.0 2022-12-08
Exciter VCXO
To view the front panel’s VCXO Calibration screens, select Exciter VCXO from the Settings ->
Transmitter menu. See
The 10 MHz Delta and VCXO 10 MHz Calibration values are for display only and are not user adjustable.
NOTE
:
An external 10 MHz source must be connected to the transmitter and External 10 MHz disabled
(refer to
Figure 2.2.104 on page 2.2.126
and
Ext 10 MHz Input on page 2.2.139
run the calibration routine.
From the Exciter VCXO screen, use the Front Panel rotary knob to select
Run VCXO 10 MHz Calibration.
The calibration routine will begin when the external 10 MHz source is connected.
Figure 2.2.111: Exciter VCXO
Remote I/O
NOTE
:
The Exciter PWB (A1) contains a jumper (E1) that allows the user to configure the Remote I/O
supply voltage. The factory setting is pins 2 and 3 for internal supply (+12V-OP). To use an external
supply voltage for remote inputs, jumper (E1) must be moved to pins 1 and 2 (+12V).
To view the Remote I/O screen (see
Figure 2.2.112 on page 2.2.131
) on the front panel display, select
Settings -> Transmitter-> Remote I/O from the Main Menu. Use the Front Panel rotary knob to select
Remote Inputs (see
) or Analog Outputs (see
Analog Outputs on page 2.2.132
) to view or edit details on the
selected inputs or output.
Summary of Contents for VX150
Page 2: ......
Page 4: ......
Page 6: ...VX150 TO VX2 OPERATIONS MAINTENANCE MANUAL TABLE OF CONTENTS PAGE VI VERSION 1 0 2022 12 08...
Page 8: ...VX LP OPERATIONS MAINTENANCE MANUAL PAGE VIII VERSION 1 0 2022 12 08...
Page 14: ...VX150 TO VX2 OPERATIONS MAINTENANCE MANUAL DESCRIPTION PAGE 2 1 6 VERSION 1 0 2022 12 08...
Page 177: ...VX LP INSTALLATION MANUAL LIST OF TERMS PAGE 1 14 2 VERSION 1 0 2022 12 08...
Page 178: ......