VX150 TO VX2 OPERATIONS & MAINTENANCE MANUAL
OPERATING THE TRANSMITTER
PAGE 2.2.76
VERSION 1.0 2022-12-08
Analog Outputs
There are two analog outputs - forward power and reflected power - that can be remotely monitored.
These outputs are factory defined parameters and cannot be changed to other parameters, however
their scaling can be configured, using the Analog Outputs page (see
), to reflect the output
voltage that yields a full-scale deflection.
Figure 2.2.48: Remote I/O - Analog Outputs Page
The values associated with each of these fixed meters are of a linear nature so that changes made to
the Sample Full Scale field (allowable range is 1- 10 V, defaulted to 5 V) will be reflected in the other
fields according to the following equation:
(
Meter Value
/
Meter Full Scale
) x
Sample Full Scale
=
Sample Voltage
NOTE
:
The Sample Voltage reading reflects the value that can be measured at the associated remote
analog output pin for the given Meter Value. See the Installation Manual for actual remote analog
output pin assignments.
Set the Sample Full Scale field, as desired, and Click the associated save button to activate the change.
Save