VX150 TO VX2 OPERATIONS & MAINTENANCE MANUAL
OPERATING THE TRANSMITTER
VERSION 1.0 2022-12-08
PAGE 2.2.75
Select Output Channel
From the editing screen for remote output 1 through 6, you can configure the output for one of a variety
of channel outputs. Click the Channel field’s up/down arrows to display the following options:
Unassigned. No alarm or status parameter is monitored.
RF On/Off. The active logic level indicates the transmitter’s RF power stage is on (enabled).
The inactive logic level indicates the transmitter’s RF power stage is off.
RF Output Fault. The active logic level indicates that an alarm is occurring that affects the RF
output (power inhibition or power reduction).
Preset 1 Active. Preset 1’s output will be indicated by a logic low. The remaining, non-active
preset outputs will be open collector.
Preset 2 Active. Preset 2’s output will be indicated by a logic low. The remaining, non-active
preset outputs will be open collector.
Remote Status. An active logic low level indicates remote control is enabled (i.e., local plus
remote). The inactive logic level indicates remote control is disabled.
Overall Summary Alarm. The active logic level indicates that an alarm is occurring. Any
transmitter alarm can be selected as a remote output. Refer to the Troubleshooting Manual
for a description of each alarm.
Click Save to activate changes. Click Cancel to cancel changes and return to the Remote Outputs
screen. If you save a change to a remote output via the AUI, it will also be displayed on the FPUI.
Configure Output Logic
You can configure the active/inactive logic for each of the six remote outputs. Click the Control field’s
up/down arrows to display and select one of the following:
Active Low. Logic ‘0’ (low) indicates the output is true (e.g., RF is on); Logic ‘1’ (high) indicates
the output is false (e.g., RF is off).
Active High. Logic ‘1’ (high) indicates the output is true (e.g., RF is on); Logic ‘0’ (low)
indicates the output is false (e.g., RF is off).
Click Save to activate changes. Click Cancel to cancel changes and return to the Remote Outputs
screen.
Summary of Contents for VX150
Page 2: ......
Page 4: ......
Page 6: ...VX150 TO VX2 OPERATIONS MAINTENANCE MANUAL TABLE OF CONTENTS PAGE VI VERSION 1 0 2022 12 08...
Page 8: ...VX LP OPERATIONS MAINTENANCE MANUAL PAGE VIII VERSION 1 0 2022 12 08...
Page 14: ...VX150 TO VX2 OPERATIONS MAINTENANCE MANUAL DESCRIPTION PAGE 2 1 6 VERSION 1 0 2022 12 08...
Page 177: ...VX LP INSTALLATION MANUAL LIST OF TERMS PAGE 1 14 2 VERSION 1 0 2022 12 08...
Page 178: ......