VX150 TO VX2 OPERATIONS & MAINTENANCE MANUAL
OPERATING THE TRANSMITTER
PAGE 2.2.136
VERSION 1.0 2022-12-08
Turn-on Delay
Allows the user to delay the start-up (RF on) of the transmitter when recovering from an Ac power loss,
in order to limit the simultaneous power demand for multiple transmitters on a common generator by
staggering their turn on sequence. See
. Allowable range is 0-120 seconds, default is 0
seconds (disabled).
Figure 2.2.120: Turn-on Delay
Ramp-up Speed
Allows the user to alter the transmitter’s start-up speed of the transmitter when recovering from an Ac
power loss. This setting establishes the time it takes the transmitter to ramp up from 0 W to full power.
This setting directly increases the system’s speed to reach full power. Normally the transmitter will take
about 7 seconds to reach full power. For example if the desired ramp up time is 30 seconds, then the
ramp-up setting should be set to 23 seconds. In multi-transmitter systems that are on a common
generator or power grid, adjusting the ramp-up speed can be used to reduce the transient load on the
source during an ac power recovery. See
Use the Front Panel rotary knob to edit the Ramp-Up Speed between 0 (default) and 600 seconds. Press
the Front Panel rotary knob to save the change. Press Cancel button to discard any changes and return
to the previous menu.
Summary of Contents for VX150
Page 2: ......
Page 4: ......
Page 6: ...VX150 TO VX2 OPERATIONS MAINTENANCE MANUAL TABLE OF CONTENTS PAGE VI VERSION 1 0 2022 12 08...
Page 8: ...VX LP OPERATIONS MAINTENANCE MANUAL PAGE VIII VERSION 1 0 2022 12 08...
Page 14: ...VX150 TO VX2 OPERATIONS MAINTENANCE MANUAL DESCRIPTION PAGE 2 1 6 VERSION 1 0 2022 12 08...
Page 177: ...VX LP INSTALLATION MANUAL LIST OF TERMS PAGE 1 14 2 VERSION 1 0 2022 12 08...
Page 178: ......