3-51
Memory Switch 000 — Dialer
Switch
Initial
Setting
Adjust
Usage/Comments
7
0
Factory use only
6
0
Factory use only
5
0
CED detection condition
Sets whether the detection should be strict or not.
Normal
Strict
350ms 500ms 700ms 1000ms
Switch 5 0 0 1 1
4 0 1 0 1
4
0
3
0
DIS detect time after dialing
0: 55 sec
1: 70 sec
Sets the time DIS signal is detected after dialing a
number.
2
1
CED detection
0: No
1: Yes
Can be use to ignore CED detection if noise on
the telephone line is mistaken as a 2100 Hz CED
signal.
1
1
Dial tone detection
0: Do not dial
1: Dial
Determines if the machine proceeds with dialing or
indicates an error if no dial tone is detected within
five seconds of going off-hook.
0
0
Phone line type for the first
phone line
0: PSTN
1: PBX
When set to PSTN, the machine checks for dial
tone and acts according to the setting of memory
switch 000, bit 1. When set to PBX, the machine
always dials a given number of seconds after going
off-hook. Memory switch 001 sets the number of
seconds.
Summary of Contents for F-525
Page 65: ...2 12 2 4 Interconnect Block Diagram See the attached files...
Page 188: ...3 104 3 8 3 How to see the print out Example for fax transmission...
Page 252: ...3 168 6 Click OK 7 Click Next The driver will be installed on the PC...
Page 253: ...3 169 8 Click Finish and finish the Found New Hardware Wizard...
Page 263: ...3 179...
Page 264: ...3 180...
Page 353: ...5 63 6 Remove one bearing and slide out the ROLLER FEED DUPLEX ROLELR FFED DUPLEX...
Page 382: ......
Page 383: ......