3-79
3.7 Unique Switch Adjustment
3.7.1 Setting the Unique Switches
These switches are used to program internal machine parameters. The primary back up battery
maintains these settings if power is lost.
1. From standby, press <Setting>, <*>, <0>, <4>
.
2. Press [Switch Edit]
.
3. Call up the desired switch by pressing [
q
]
or [
p
]
, or by pressing the numeric keypad.
4. Select the desired switch by pressing the box.
5. To navigate through the unique switch settings:
•
The bits are ranged from 7 (left) to 0 (right).
•
Press [ ]or[ ] of the cursor key to move the cursor.
•
Press <0> or <1>
on the numeric keypad, or [
q
]
or [
p
]
, to change the bit value.
•
Press [Enter] to save the setting of the displayed unique switch and return to the unique
switch edit screen.
•
Press [Back] not to save the setting of the displayed unique switch.
6. If you want to set other unique switches, repeat step 3-5. Otherwise, proceed to step 7.
7. Press [Reset] to return the machine to standby.