3-13
Machine Parameter 033
Switch
Initial
Setting
Adjust
Usage/Comments
7
0
Scanning density level
adjustment in hyper-fine
resolution.
Switch 76543210
01111111 Darkest setting
:
00001000
:
00000000
Initial setting
:
10001000
:
11111111 Lightest setting
6
0
5
0
4
0
3
0
2
0
1
0
0
0
Machine Parameter 034
Switch
Initial
Setting
Adjust
Usage/Comments
7
0
Scanning density level
adjustment in hyper-fine
(600dpi x 600dpi) resolution.
Switch 76543210
01111111 Darkest setting
:
00001000
:
00000000
Initial setting
:
10001000
:
11111111 Lightest setting
6
0
5
0
4
0
3
0
2
0
1
0
0
0
Machine Parameter 035 ~ 089 — Factory use only