3-118
If some portion of the read/write test fails, the display will show “NG” with the address and the data
name.
3. Upon completion, the machine returns to the test mode.
3.13.6 DRAM Check
This mode is used to test the DRAM memory, or document memory.
Note:
When this test is performed, an All DRAM Clear will be performed by the unit. The All RAM
clear erases all user settings and resets all memory switches, machine parameters and unique
switches to factory defaults.
This is a read/write test that requires a few moments to complete.
Note:
Perform a DRAM test whenever a memory upgrade is added to the unit.
1. Press <Setting>, <*>, <1>, <1>, then select [DRAM Check].
2. Enter the HEX code (00 ~ FF) using numeric keypad and one-touch key [01] to [06], then press
<Start>.
3. Depending on the amount of DRAM in the unit, press <0>, <1>, <2>, or <3> on the numeric key-
pad.
Please refer to the following table:
Note:
Usually, press <0>.
Press
Check area
0
All DRAMs
1
The standard memory on the main control board
2
The first half of the 32MB Optional Memory PCB
3
The second half of the 32MB Optional Memory PCB
4. Press <Start>
.
The machine starts checking and the result (OK/NG) will be shown in the display.
For example, if the check area is “0” and one additional memory, you will see:
Summary of Contents for F-525
Page 65: ...2 12 2 4 Interconnect Block Diagram See the attached files...
Page 188: ...3 104 3 8 3 How to see the print out Example for fax transmission...
Page 252: ...3 168 6 Click OK 7 Click Next The driver will be installed on the PC...
Page 253: ...3 169 8 Click Finish and finish the Found New Hardware Wizard...
Page 263: ...3 179...
Page 264: ...3 180...
Page 353: ...5 63 6 Remove one bearing and slide out the ROLLER FEED DUPLEX ROLELR FFED DUPLEX...
Page 382: ......
Page 383: ......