4. CONNECTION TO FUJI PLC
4.6 Device Range that Can Be Set
*1
Only reading is possible.
*2
Only 32-bit (2-word) designation is allowed.
*3
Decimal points are not displayed.
*4
To read/write data from/to a user file, set SI data for the data
format of the PLC CPU and 16 bits for data length on GT
Designer3.
With any setting other than the above, the PLC does not
operate normally.
*5
As bit specification of a word device is performed after the
GOT reads the value, do not change the value in the
sequence program during this period.
*6
When it is used with bit specification (bit specification of word
device), the offset function cannot be used.
*7
When bit specification (bit specification of word device) is
performed, the uppermost bit is b0 and the lowermost bit is
b15.
W
o
rd device
Differential relay
(WD)
WD000 to WD063
Decimal
Link memory (WL)
WL000 to WL511
Direct access
(W24)
*6*7
W24:0000 to W24:0255
User file (W30)
*4*6*7
User file (W31)
*4*6*7
:
User file
(W108)
*4*6*7
User file
(W109)
*4*6*7
W30:0000 to W30:4095
W31:0000 to W31:4095
:
W108:0000 to W108:4095
W109:0000 to W109:4095
Decimal
Data memory
(BD)
*2
BD0 to BD4095
Timer set value
(0.01s) (TS)
*2*3
TS0 to TS511
Timer current value
(0.01s) (TR)
*2*3
TR0 to TR511
Timer current value
(0.1s) (W9)
*2*3
W9:0000 to W9:0487
Counter set value
(CS)
*2*3
CS0 to CS511
Counter current
value (CR)
*2*3
CR0 to CR511
Data format of the PLC
CPU
GT Designer3 setting
SI (Binary 16-bit length)
Device data bit: 16 bits
DI (Binary 32-bit length)
Cannot be used
BD (8-digit BCD)
Cannot be used
Higher
Lower
b0
b1
..........
b14
b15
Device name
Setting range
Device No.
representation
Summary of Contents for GOT2000Series
Page 2: ......
Page 17: ...A 15 REVISIONS WARRANTY...
Page 52: ...1 30 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring...
Page 54: ......
Page 78: ...3 10 3 CONNECTION TO HITACHI PLC 3 6 Device Range that Can Be Set...
Page 100: ...4 22 4 CONNECTION TO FUJI PLC 4 7 Precautions...
Page 174: ...7 24 7 CONNECTION TO YOKOGAWA PLC 7 4 Device Range that Can Be Set...
Page 262: ...9 54 9 CONNECTION TO RKC TEMPERATURE CONTROLLER 9 7 Precautions...
Page 280: ...10 18 10 CONNECTION TO ALLEN BRADLEY PLC 10 4 Device Range that Can Be Set...
Page 296: ...11 16 11 CONNECTION TO GE PLC 11 7 Precautions...
Page 308: ...12 12 12 CONNECTION TO LS INDUSTRIAL SYSTEMS PLC 12 6 Device Range that Can Be Set...
Page 332: ...14 18 14 CONNECTION TO SIEMENS PLC 14 4 Device Range that Can Be Set...
Page 334: ...REVISIONS 2...
Page 337: ......