14. CONNECTION TO SIEMENS PLC
14.2 Serial Connection
14 - 7
CONNECTION T
O
SIEME
N
S PLC
14
(2) SIEMENS S7-200
POINT
POINT
POINT
(1) Communication interface setting by the Utility
The communication interface setting can be
changed on the Utility's [Communication setting]
after writing [Communication Settings] of project
data.
For details on the Utility, refer to the following
manual.
GOT2000 Series User's Manual (Utility)
(2) Precedence in communication settings
When settings are made by GT Designer3 or the
Utility, the latest setting is effective.
14.2.5
PLC Side Setting
POINT
POINT
POINT
SIEMENS PLC
For details of SIEMENS PLCs, refer to the following
manuals.
SIEMENS PLC user's Manual
14.2.6
Connecting to HMI Adapter
Communication settings
The following communication settings are made at the
communication detail settings of the GOT side.
For details, refer to the following.
Item
Description
Range
Transmission
Speed
Set this item when change the
transmission speed used for
communication with the connected
equipment.
(Default: 19200bps)
9600bps,
19200bps,
38400bps,
57600bps,
115200bps
Data Bit
Set this item when change the data
length used for communication with
the connected equipment.
(Default: 8bits)
7bits/8bits
Stop Bit
Specify the stop bit length for
communications.
(Default: 1bit)
1bit/2bits
Parity
Specify whether or not to perform a
parity check, and how it is performed
during communication.
(Default: Even)
None
Even
Odd
Adapter Address
Specify the adapter address (station
No. of the adapter to which the GOT
is connected) in the connected
network.
(Default: 0)
0 to 31
Host Address
Specify the host address (station No.
of the PLC that the GOT will monitor)
in the connected network.
(Default: 2)
1 to 31
Model name
Refer to
PLC CPU
S7-200
HMI Adapter
6ES7 972-0CA11-0XA0
PC/PPI cable
6ES7 901-3BF20-0XA0
6ES7 901-3CB30-0XA0
Setting item
PLC side setting
Transmission speed
9600bps, 19200bps, 38400bps
Data bit
8bits (fixed)
Parity bit
Odd (fixed)
Stop bit
1bit (fixed)
Adapter address
1 to 31
Host address
1 to 31
Summary of Contents for GOT2000Series
Page 2: ......
Page 17: ...A 15 REVISIONS WARRANTY...
Page 52: ...1 30 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring...
Page 54: ......
Page 78: ...3 10 3 CONNECTION TO HITACHI PLC 3 6 Device Range that Can Be Set...
Page 100: ...4 22 4 CONNECTION TO FUJI PLC 4 7 Precautions...
Page 174: ...7 24 7 CONNECTION TO YOKOGAWA PLC 7 4 Device Range that Can Be Set...
Page 262: ...9 54 9 CONNECTION TO RKC TEMPERATURE CONTROLLER 9 7 Precautions...
Page 280: ...10 18 10 CONNECTION TO ALLEN BRADLEY PLC 10 4 Device Range that Can Be Set...
Page 296: ...11 16 11 CONNECTION TO GE PLC 11 7 Precautions...
Page 308: ...12 12 12 CONNECTION TO LS INDUSTRIAL SYSTEMS PLC 12 6 Device Range that Can Be Set...
Page 332: ...14 18 14 CONNECTION TO SIEMENS PLC 14 4 Device Range that Can Be Set...
Page 334: ...REVISIONS 2...
Page 337: ......