![Mitsubishi GOT2000Series Connection Manual Download Page 170](http://html1.mh-extra.com/html/mitsubishi/got2000series/got2000series_connection-manual_1809187170.webp)
7 - 20
7. CONNECTION TO YOKOGAWA PLC
7.3 Ethernet Connection
(2) Condition setting switch
Set the data format, write protection, line processing at
TCP timeout error or operation mode with the DIP
switch on the side of the base unit.
*1
Applicable to only F3LE01-5T.
7.3.5
Connecting to Ethernet
Interface Module (F3LE12-0T)
Switch settings of Ethernet Interface Module
Set the switches accordingly.
POINT
POINT
POINT
Switch setting
Set the switches before mounting the Ethernet
Interface Module on the base unit.
(1) IP address switch
Set the IP address with eight Hex rotary switches on
the side of the base unit.
(2) Condition setting switch
Set the data format, write protection, or operation mode
with the DIP switch on the side of the base unit.
Switch
No.
Description
Set value
1
Data
code
OFF (ASCII)
2
Write
protect
OFF (not protect)
3
Reserved
ON (not available),
OFF (always)
4
5
6
7
Line
processing
on TCP
timeout
*1
OFF (close the line)
8
Operation
mode
OFF (normal operation)
1 2 3 4 5 6 7 8
OFF
Switch
No.
Description
Set value
1
Data code
OFF (ASCII)
2
Write protect
OFF (not protect)
3
Reserved
ON (not available),
OFF (always)
4
5
6
7
8
Operation
mode
OFF (normal operation)
F3LE12-0T
Condition setting switch
IP address switch
Right side view with the cover
0 12
3
4
5
67
89
AB
C
D
EF
0 12
3
4
5
67
89
AB
C
D
EF
0 12
3
4
5
67
89
AB
C
D
EF
0 12
3
4
5
67
89
AB
C
D
EF
0 12
3
4
5
67
89
AB
C
D
EF
0 12
3
4
5
67
89
AB
C
D
EF
0 12
3
4
5
67
89
AB
C
D
EF
0 12
3
4
5
67
89
AB
C
D
EF
Hexadecimal
Decimal
C0
A8
FA
D2
192
168
250
210
1 2 3 4 5 6 7 8
OFF
Summary of Contents for GOT2000Series
Page 2: ......
Page 17: ...A 15 REVISIONS WARRANTY...
Page 52: ...1 30 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring...
Page 54: ......
Page 78: ...3 10 3 CONNECTION TO HITACHI PLC 3 6 Device Range that Can Be Set...
Page 100: ...4 22 4 CONNECTION TO FUJI PLC 4 7 Precautions...
Page 174: ...7 24 7 CONNECTION TO YOKOGAWA PLC 7 4 Device Range that Can Be Set...
Page 262: ...9 54 9 CONNECTION TO RKC TEMPERATURE CONTROLLER 9 7 Precautions...
Page 280: ...10 18 10 CONNECTION TO ALLEN BRADLEY PLC 10 4 Device Range that Can Be Set...
Page 296: ...11 16 11 CONNECTION TO GE PLC 11 7 Precautions...
Page 308: ...12 12 12 CONNECTION TO LS INDUSTRIAL SYSTEMS PLC 12 6 Device Range that Can Be Set...
Page 332: ...14 18 14 CONNECTION TO SIEMENS PLC 14 4 Device Range that Can Be Set...
Page 334: ...REVISIONS 2...
Page 337: ......