9. CONNECTION TO RKC TEMPERATURE CONTROLLER
9.6 Device Range that Can Be Set
9.6
Device Range that Can Be Set
The device ranges of controller that can be used for GOT are as follows.
Note that the device ranges in the following tables are the maximum values that can be set in GT Designer3.
The device specifications of controllers may differ depending on the models, even though belonging to the same series.
Please make the setting according to the specifications of the controller actually used.
When a non-existent device or a device number outside the range is set, other objects with correct device settings may
not be monitored.
Setting item
*1
The following shows the relation between station numbers of the temperature controller and the GOT data register.
POINT
POINT
POINT
Device settings of RKC temperature controller
Item
Description
Device
Set the device name, device number, and bit number.
The bit number can be set only when specifying the bit of word device.
Information
Displays the device type and setting range which are selected in [Device].
Network
Set the monitor target of the set device.
Station No.
To monitor the temperature controller of the specified station No.
1 to 99
:To monitor the temperature controller of the specified station No.
100 to 115
To specify the station No. of the temperature controller to be monitored by the value of GOT data
register (GD).
*1
Station No.
GOT data register (GD)
Setting range
100
GD10
1 to 99
(If setting a value outside
the range above, a device
range error occurs.)
101
GD11
:
:
114
GD24
115
GD25
Set by a value of "unit a 1".
• For unit address 0: Set "1".
• For unit address F: Set "16".
Summary of Contents for GOT2000Series
Page 2: ......
Page 17: ...A 15 REVISIONS WARRANTY...
Page 52: ...1 30 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring...
Page 54: ......
Page 78: ...3 10 3 CONNECTION TO HITACHI PLC 3 6 Device Range that Can Be Set...
Page 100: ...4 22 4 CONNECTION TO FUJI PLC 4 7 Precautions...
Page 174: ...7 24 7 CONNECTION TO YOKOGAWA PLC 7 4 Device Range that Can Be Set...
Page 262: ...9 54 9 CONNECTION TO RKC TEMPERATURE CONTROLLER 9 7 Precautions...
Page 280: ...10 18 10 CONNECTION TO ALLEN BRADLEY PLC 10 4 Device Range that Can Be Set...
Page 296: ...11 16 11 CONNECTION TO GE PLC 11 7 Precautions...
Page 308: ...12 12 12 CONNECTION TO LS INDUSTRIAL SYSTEMS PLC 12 6 Device Range that Can Be Set...
Page 332: ...14 18 14 CONNECTION TO SIEMENS PLC 14 4 Device Range that Can Be Set...
Page 334: ...REVISIONS 2...
Page 337: ......