7. CONNECTION TO YOKOGAWA PLC
7.4 Device Range that Can Be Set
7 - 23
7
CONN
ECTION
T
O
YOKOGA
W
A
PLC
7.4.1
YOKOGAWA FA500/FA-M3
Series
*1
Writing is not possible.
*2
Writing to continuous devices is not possible.
*3
The GOT cannot read or write data from/to consecutive
devices.
7.4.2
YOKOGAWA STARDOM/FA-
M3 Series
*1
Writing is not possible.
*2
Writing to continuous devices is not possible.
*3
The GOT cannot read or write data from/to consecutive
devices.
*4
With STARDOM, FA-M3 (F3SP59 only), if communications
that include the maximum device number (32767 or 65535)
occurs, system alarm "322 Dedicated device is out of range.
Confirm device range." may be detected.
If such system alarm is detected, do not use the last 15 bits.
*5
With STARDOM, do not use B32768 or later. Otherwise,
normal monitoring is not performed.
Device name
Setting range
Device No.
representa
tion
Bit
device
Input relay (X)
*1
X00201 to X71664
Decimal
Output relay (Y)
Y00201 to Y71664
Internal relay (I)
I1 to I65536
Link relay (L)
L1 to L71024
Common relay (E)
E1 to E4096
Special relay (M)
*3
M1 to M9984
Timer (TU)
*2
TU1 to TU3072
Counter (CU)
*2
CU1 to CU3072
Word device bit
Specified bit of the following
word devices
(Except Timer (TP, TS),
Counter (CP, CS))
Wo
rd
d
e
v
ic
e
Timer (TP)
TP1 to TP3072
Decimal
Timer (TS)
*1
TS1 to TS3072
Counter (CP)
CP1 to CP3072
Counter (CS)
*1
CS1 to CS3072
File register (B)
B1 to B262144
Data register (D)
D1 to D8192
Common register (R)
R1 to R4096
Index register (V)
V1 to V256
Link register (W)
W1 to W71024
Special register (Z)
*3
Z1 to Z512
Bit device word
Converting bit devices into
word
(Except Timer (TU), Counter
(CU))
Device name
Setting range
Device No.
representa
tion
B
it device
Input relay (X)
*1
X00201 to X71664
Decimal
Output relay (Y)
Y00201 to Y71664
Internal relay (I)
*4
I1 to I65535
Link relay (L)
L00001 to L08192
L10001 to L18192
L20001 to L28192
L30001 to L38192
L40001 to L48192
L50001 to L58192
L60001 to L68192
L70001 to L78192
Common relay (E)
E1 to E4096
Special relay (M)
*3
M1 to M9984
Timer (TU)
*2
TU1 to TU3072
Counter (CU)
*2
CU1 to CU3072
Word device bit
Specified bit of the following
word devices
(Excluding TP, TS, CP and
CS)
W
o
rd
device
Timer (TP)
TP1 to TP3072
Decimal
Timer (TS)
*1
TS1 to TS3072
Counter (CP)
CP1 to CP3072
Counter (CS)
*1
CS1 to CS3072
Filer register (B)
*5
B1 to B262144
Data register (D)
D1 to D65535
Common register (R)
R1 to R4096
Index register
V1 to V256
Link register (W)
W00001 to W08192
W10001 to W18192
W20001 to W28192
W30001 to W38192
W40001 to W48192
W50001 to W58192
W60001 to W68192
W70001 to W78192
Special register (Z)
*3
Z1 to Z1024
Bit device word
Converting bit devices into
word
(Except TU and CU)
Summary of Contents for GOT2000Series
Page 2: ......
Page 17: ...A 15 REVISIONS WARRANTY...
Page 52: ...1 30 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring...
Page 54: ......
Page 78: ...3 10 3 CONNECTION TO HITACHI PLC 3 6 Device Range that Can Be Set...
Page 100: ...4 22 4 CONNECTION TO FUJI PLC 4 7 Precautions...
Page 174: ...7 24 7 CONNECTION TO YOKOGAWA PLC 7 4 Device Range that Can Be Set...
Page 262: ...9 54 9 CONNECTION TO RKC TEMPERATURE CONTROLLER 9 7 Precautions...
Page 280: ...10 18 10 CONNECTION TO ALLEN BRADLEY PLC 10 4 Device Range that Can Be Set...
Page 296: ...11 16 11 CONNECTION TO GE PLC 11 7 Precautions...
Page 308: ...12 12 12 CONNECTION TO LS INDUSTRIAL SYSTEMS PLC 12 6 Device Range that Can Be Set...
Page 332: ...14 18 14 CONNECTION TO SIEMENS PLC 14 4 Device Range that Can Be Set...
Page 334: ...REVISIONS 2...
Page 337: ......