![Mitsubishi GOT2000Series Connection Manual Download Page 77](http://html1.mh-extra.com/html/mitsubishi/got2000series/got2000series_connection-manual_1809187077.webp)
3. CONNECTION TO HITACHI PLC
3.6 Device Range that Can Be Set
3 - 9
3
C
O
NN
ECTION T
O
HIT
ACHI PLC
*1
Only reading is possible.
*2
Only 16-bit (1-word) designation is allowed.
*3
Only 32-bit (2-word) designation is allowed.
*4
When it is used with bit specification (bit specification of word
device), the offset function cannot be used.
*5
When bit specification (bit specification of word device) is
performed, the uppermost bit is b0 and the lowermost bit is
b15.
*6
Device "GL" corresponds to device "G" of the PLC.
W
o
rd device
One-shot timer (UW)
UW000 to UW0F0
Hexadec
imal
Up-down counter (CW)
CW00 to CWF0
Global link register (GW)
GW000 to GWFF0
Event register (EW)
EW000 to EWFF0
System register (SW)
*1
SW000 to SWBF0
Transfer register (JW)
JW000 to JWFF0
Receive register (QW)
QW000 to QWFF0
On-delay timer (current
value) (TC)
*2
TC000 to TC1FF
On-delay timer (set value)
(TS)
*2
TS000 to TS1FF
One-shot timer (current
value) (UC)
*2
UC000 to UC0FF
One-shot timer (set value)
(US)
*2
US000 to US0FF
Up-down counter (current
value) (CC)
*2
CC00 to CCFF
Up-down counter (set
value) (CS)
*2
CS00 to CSFF
Function data register
(DW)
*4*5
DW000 to DWFFF
Function work register
(FW)
*4*5
FW000 to FWBFF
Extended function work
register (LWW)
*4*5
LWW0000 to LWWFFFF
Backup work register
(LXW)
*5
LXW0000 to LXW3FFF
Long-word work register
(LLL)
*3
LLL0000 to LLL1FFF
Backup Long-word work
register (LML)
*3*4
LML0000 to LML1FFF
Floating-point work register
(LF)
*3
LF0000 to LF1FFF
Backup single-precision
floating-point work register
(LG)
*3
LG0000 to LG1FFF
Higher
Lower
b0
b1
..........
b14
b15
Device name
Setting range
Device
No.
represen
tation
Summary of Contents for GOT2000Series
Page 2: ......
Page 17: ...A 15 REVISIONS WARRANTY...
Page 52: ...1 30 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring...
Page 54: ......
Page 78: ...3 10 3 CONNECTION TO HITACHI PLC 3 6 Device Range that Can Be Set...
Page 100: ...4 22 4 CONNECTION TO FUJI PLC 4 7 Precautions...
Page 174: ...7 24 7 CONNECTION TO YOKOGAWA PLC 7 4 Device Range that Can Be Set...
Page 262: ...9 54 9 CONNECTION TO RKC TEMPERATURE CONTROLLER 9 7 Precautions...
Page 280: ...10 18 10 CONNECTION TO ALLEN BRADLEY PLC 10 4 Device Range that Can Be Set...
Page 296: ...11 16 11 CONNECTION TO GE PLC 11 7 Precautions...
Page 308: ...12 12 12 CONNECTION TO LS INDUSTRIAL SYSTEMS PLC 12 6 Device Range that Can Be Set...
Page 332: ...14 18 14 CONNECTION TO SIEMENS PLC 14 4 Device Range that Can Be Set...
Page 334: ...REVISIONS 2...
Page 337: ......