14 - 16
14. CONNECTION TO SIEMENS PLC
14.4 Device Range that Can Be Set
(b) S7-200 Series
POINT
POINT
POINT
Device settings of SIEMENS PLC (S7-200 series)
(1) When setting bit devices (except Timer and
Counter)
Set the device using the byte address (DEC) and
the bit address (0 to 7).
(c) SIEMENS OP (Ethernet)
POINT
POINT
POINT
Device settings of SIEMENS PLC (S7-200/300/400/
1200 series, SIEMENS OP (Ethernet))
(1) When setting a bit device as a bit device
Set the device using the format of byte address
(DEC) + bit address (0 to 7).
(2) When setting a data register
Set the device using the format of data block
(DB) + data word (DW).
(3) Precautions when setting devices
(a) Preparing to set a data register
It is necessary to define the data block using a
peripheral software and sequence program,
before using a data register. Setting more
than one data block cannot be done for the
data register.
(b) Object that cannot be set Timer (current
value) (T)
Only one device can be set for the write target
of this device. Therefore, multiple devices,
such as, using the recipe function, etc.,
cannot be used.
(c) Notation method of the data registers with the
bit specification
The notation of the data registers with the bit
specification differs between the GOT and the
PLC. The following shows the
correspondence table.
Item
Description
Device
Set the device name, device number, and bit number.
The bit number can be set only when specifying the bit of
word device.
Description
Displays the device type and setting range which are
selected in [Device].
Item
Description
Device
Set the device name, device number, and bit number.
The bit number can be set only when specifying the bit of
word device.
Information
Displays the device type and setting range which are
selected in [Device].
Network
Set the monitor target of the set device.
Host
Select this item to monitor the controller specified
as the host station in the GOT utility (setup).
Other
Select this item to monitor a controller other than
the one specified as the host station.
Bit address (0 to 7)
Byte address (DEC)
Device name
Notation in GOT
Notation in PLC
DB1.DBW0.b0
DB1.DBX1.0
DB1.DBW0.b1
DB1.DBX1.1
:
:
DB1.DBW0.b7
DB1.DBX1.7
DB1.DBW0.b8
DB1.DBX0.0
:
:
DB1.DBW0.b15
DB1.DBX0.7
DB1.DBW2.b0
DB1.DBX3.0
:
:
DB1.DBW2.b7
DB1.DBX3.7
DB1.DBW2.b8
DB1.DBX2.0
:
:
DB1.DBW2.b15
DB1.DBX2.7
:
:
Device number
Bit address (0 to 7)
Byte address (DEC)
Device name
Data word (DW) numbe
Data block (DB) numbe
Device name
Summary of Contents for GOT2000Series
Page 2: ......
Page 17: ...A 15 REVISIONS WARRANTY...
Page 52: ...1 30 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring...
Page 54: ......
Page 78: ...3 10 3 CONNECTION TO HITACHI PLC 3 6 Device Range that Can Be Set...
Page 100: ...4 22 4 CONNECTION TO FUJI PLC 4 7 Precautions...
Page 174: ...7 24 7 CONNECTION TO YOKOGAWA PLC 7 4 Device Range that Can Be Set...
Page 262: ...9 54 9 CONNECTION TO RKC TEMPERATURE CONTROLLER 9 7 Precautions...
Page 280: ...10 18 10 CONNECTION TO ALLEN BRADLEY PLC 10 4 Device Range that Can Be Set...
Page 296: ...11 16 11 CONNECTION TO GE PLC 11 7 Precautions...
Page 308: ...12 12 12 CONNECTION TO LS INDUSTRIAL SYSTEMS PLC 12 6 Device Range that Can Be Set...
Page 332: ...14 18 14 CONNECTION TO SIEMENS PLC 14 4 Device Range that Can Be Set...
Page 334: ...REVISIONS 2...
Page 337: ......