12. CONNECTION TO LS INDUSTRIAL SYSTEMS PLC
12.6 Device Range that Can Be Set
12 - 11
CONNECTION T
O
LS INDUSTRIA
L SY
STEMS PLC
12
12.6 Device Range that Can Be Set
The device ranges of controller that can be used for GOT
are as follows.
Note that the device ranges in the following tables are the
maximum values that can be set in GT Designer3.
The device specifications of controllers may differ
depending on the models, even though belonging to the
same series.
Please make the setting according to the specifications of
the controller actually used.
When a non-existent device or a device number outside
the range is set, other objects with correct device settings
may not be monitored.
Setting item
*1
The following shows the relation between station numbers of
the PLC and the GOT data register.
POINT
POINT
POINT
Device settings of LS IS PLC
(1) When setting bit device (except timer and
counter)
Set the bit device using the decimal number (three
digits) and the hexadecimal number.
12.6.1
LS Industrial Systems
MASTER-K
*1
Only reading is possible.
Item
Description
Device
Set the device name, device number, and bit number.
The bit number can be set only when specifying the bit of
word device.
Informati
on
Displays the device type and setting range which are
selected in [Device].
Network
Set the monitor target of the set device.
Station
No.
Monitors the PLC of the specified station No.
0 to 31
: To monitor the PLC of the specified
station No.
100 to 115
: To specify the station No. of the PLC
to be monitored by the value of GOT
data register (GD).
*1
Statio
n No.
GOT data register (GD)
Setting range
100
GD10
0 to 31
(If setting a value
outside the range
above, a device
range error
occurs.)
101
GD11
:
:
114
GD24
115
GD25
Device name
Setting range
Device
No.
represent
ation
Bit
device
I/O relay (P)
P0000 to P063F
D
Hexadeci
mal
Auxiliary relay (M)
M0000 to M191F
Keep relay (K)
K0000 to K031F
Link relay (L)
L0000 to L063F
Special relay (F)
*1
F0000 to F063F
Timer contact (T)
T0 to T255
Decimal
Counter contact (C)
C0 to C255
Wo
rd
d
e
v
ic
e
I/O relay (P)
P000 to P063
Decimal
Auxiliary relay (M)
M000 to M191
Keep relay (K)
K000 to K031
Link relay (L)
L000 to L063
Special relay (F)
*1
F000 to F063
Timer current value (T)
T0 to T255
Counter current value (C)
C0 to C255
Step controller (S)
S0 to S99
Data register (D)
D0 to D9999
Device number
HEX
DEC
Device name
Summary of Contents for GOT2000Series
Page 2: ......
Page 17: ...A 15 REVISIONS WARRANTY...
Page 52: ...1 30 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring...
Page 54: ......
Page 78: ...3 10 3 CONNECTION TO HITACHI PLC 3 6 Device Range that Can Be Set...
Page 100: ...4 22 4 CONNECTION TO FUJI PLC 4 7 Precautions...
Page 174: ...7 24 7 CONNECTION TO YOKOGAWA PLC 7 4 Device Range that Can Be Set...
Page 262: ...9 54 9 CONNECTION TO RKC TEMPERATURE CONTROLLER 9 7 Precautions...
Page 280: ...10 18 10 CONNECTION TO ALLEN BRADLEY PLC 10 4 Device Range that Can Be Set...
Page 296: ...11 16 11 CONNECTION TO GE PLC 11 7 Precautions...
Page 308: ...12 12 12 CONNECTION TO LS INDUSTRIAL SYSTEMS PLC 12 6 Device Range that Can Be Set...
Page 332: ...14 18 14 CONNECTION TO SIEMENS PLC 14 4 Device Range that Can Be Set...
Page 334: ...REVISIONS 2...
Page 337: ......