9. CONNECTION TO RKC TEMPERATURE CONTROLLER
9.5 Temperature Controller Side Setting
(3) Unit address settings
Set the unit address using the unit address setting
switch.
(4) Interval time settings
Configure the interval time setting using the RKC
communication setting tool (WinPCI).
After the communication is started, set as follows.
For the using method of RKC communication setting
tool, refer to the following.
RKC communication setting tool user's manual
9.5.4
Connecting to Z-COM
(1) Communication settings
*1
Adjust the settings with GOT settings.
*2
Select the unit address without overlapping with that of other
units.
(2) Setting DIP switches
Make the settings of transmission speed, data bit
configuration, communication protocol.
Setting item
Set value
Instrument
0
CFG file
ZTIO_rkc.cfg
Interval time
0 to 250ms
Module address setting switch
Setting range : 0 to F
Item
Setting range
Communication speed
*1
9600bps, 19200bps, 38400bps
Communication protocol
Host (MODBUS)
Data bit
8bits (fixed)
Parity
None (fixed)
Stop bit
1bit (fixed)
Unit address
*2
0 to F
Interval time
0 to 250ms
Dip switch settings
valid / invalid
valid
Setting item
Set value
Switch position
1
2
3
4
5
6
7
8
Communication
speed
(COM1)
9600bps
ON OFF
19200bps OFF ON
38400bps
ON
ON
Communication
protocol
(COM1)
Host
(MODBUS)
ON
Communication
speed
(COM2)
9600bps
OFF
19200bps
ON
Communication
protocol
(COM2)
Host
(MODBUS)
ON OFF OFF
Dip
switch settings
valid / invalid
valid
OFF
12345678
ON
OFF ON
COM.
PORT1
COM.
PORT2
COM.
PORT3
COM.
PORT4
COM1
COM2
Front side
Right side
Dip switch
COM
Summary of Contents for GOT2000Series
Page 2: ......
Page 17: ...A 15 REVISIONS WARRANTY...
Page 52: ...1 30 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring...
Page 54: ......
Page 78: ...3 10 3 CONNECTION TO HITACHI PLC 3 6 Device Range that Can Be Set...
Page 100: ...4 22 4 CONNECTION TO FUJI PLC 4 7 Precautions...
Page 174: ...7 24 7 CONNECTION TO YOKOGAWA PLC 7 4 Device Range that Can Be Set...
Page 262: ...9 54 9 CONNECTION TO RKC TEMPERATURE CONTROLLER 9 7 Precautions...
Page 280: ...10 18 10 CONNECTION TO ALLEN BRADLEY PLC 10 4 Device Range that Can Be Set...
Page 296: ...11 16 11 CONNECTION TO GE PLC 11 7 Precautions...
Page 308: ...12 12 12 CONNECTION TO LS INDUSTRIAL SYSTEMS PLC 12 6 Device Range that Can Be Set...
Page 332: ...14 18 14 CONNECTION TO SIEMENS PLC 14 4 Device Range that Can Be Set...
Page 334: ...REVISIONS 2...
Page 337: ......